Search:
1U RedundantR1S2-5120V0H

120W

Server ,Workstation ,Storage System

150x176x41.8(mm)
5.91x6.93x1.65(inch)

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 10 ±5% ±1% 50mV
+12V 2 10 ±5% ±1% 120mV
-12V 0 0.3 ±5% ±1% 120mV
+3.3V 0 10 ±5% ±1% 50mV
+5VSB 0.1 3 ±5% ±1% 50mV
* POWER MODULE TOTAL OUTPUT POWER OF +3.3V AND +5V NOT EXCEED 80W
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 120W


* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:TYPICAL 85% AT 230V, 50% OF FULL LOAD
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET UL&CUL, TUV
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.