Search:
PS2*2 RedundantRHI-4630V0V

630W

Server ,Workstation ,IPC

183x170x171(mm)
7.2x6.69x6.73(inch)

VOLTAGE: 90~264 VAC FULL RANGE
INRUSH CURRENT: 20/40 amps @115/230 VAC (at 25 degrees ambient cold start for each power unit)
PFC: Up to the target of 95% @115/230VAC, full load
Efficiency: The maximum power supply system efficiency shall be 84.8%, measured at nominal input voltage 230 V and full loading


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 75 +6/-2% ±1% 50mV
+12V 1 20 ±5% ±1% 120mV
-12V 0 1 ±5% ±1% 120mV
+5VSB 0.1 3.5 ±5% ±1% 50mV


*TEMPERATURE RANGE : OPERATING 0℃ ~ 50℃, STORAGE –20℃ ~ 80℃
* HUMIDITY:OPERATING: 20%~80%, NON-OPERATING:10%~90%
* PROTECTION: OPP/OVP/OCP/SCP
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: UL 60950/CUL CSA 22.2 No.60950/TUV EN-60950/CCC
* LEAKAGE CURRENT: Less than 3.5mA rms. Measurement will be made at 240 VAC and 60Hz.

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.