Search:
Mini 1U SingleP1S-2120V

120W

Server ,Workstation ,Storage System ,IPC ,Blade server

120x81.5x40.3(mm)
4.72x3.21x1.59(inch)

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A(RMS) FOR 115 VAC / 1A(RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE /
70A MAX. FOR 230 VAC PER MODULE


Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 1 10 ±5% ±1% 120mV
+5V 0 10 ±5% ±1% 50mV
* POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 120W

* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT +12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* EFFICIENCY:85% AT 230VAC, 50% MAX LOAD
* LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:105~150% MAX
* OVER VOLTAGE PROTECTION: +12V→12.8~15V; +5V→5.7~7V
* OVER CURRENT PROTECTION: +12V→110~150% * SHORT CIRCUIT PROTECTION: +12V
* SAFETY: MEET UL, CUL, TUV, CCC

*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module