Search:
1U RedundantDS1Z-2800V

800W

Server ,Workstation ,IPC ,Blade server ,Communication

205.5x83x39(mm)
8.09x3.27x1.54(inch)

VOLTAGE: DC –36 ~ –72VDC (Normal: -48VDC)
STEADY-STATE CURRENT: -36 ~ -72 VDC / 30~15 AMP (22 AMP AT -48VDC)
INRUSH CURRENT: 10 AMPS MAX. @-48VDC (AT 25 DEGREES AMBIENT COLD START)


Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 2 66 ±5% ±1% ±120mV
+5VSB 0.1 3 ±5% ±1% ±50mV


* TEMPERATURE RANGE: OPERATING 0℃ ~ 50℃, STORAGE -20℃~80℃
* EFFICIENCY: SHALL BE 85% @ -48V AND 50% LOADING
* OVER POWER PROTECTION: 110~150%
* OVER VOLTAGE PROTECTION: +12V→ +12.8V~+13.9V
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
* MEET SAFETY: UL, CUL, TUV, CCC

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module