Search:
N+1 RedundantR2K-5800K2V

800W

Server ,Workstation ,Storage System ,IPC

340x101x82(mm)
13.39x3.98x3.23(inch)

Input:VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63Hz.
INPUT CURRENT: 6A (RMS) FOR 230 VAC / 12A (RMS) FOR 115 VAC
INRUSH CURRENT: 30A MAX. FOR 115 VAC PER MODULE / 60A MAX. FOR 230 VAC PER MODULE
PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD


Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1 32 ±5% ±1% 50mV
+12V 2 67 ±5% ±1% 120mV
-12V 0 0.5 ±5% ±1% 120mV
+3.3V 1 32 ±5% ±1% 50mV
+5VSB 0.1 3.5 ±5% ±1% 50mV


* TEMPERATURE RANGE: OPERATING 0℃~40℃,STORAGE -20℃~80℃
* EFFICIENCY: TYPICAL 84.6% AT 230V AND FULL LOADING
* OVER POWER PROTECTION: 110 ~ 160% MAX
* OVER VOLTAGE PROTECTION: +5V → 5.8V ~ 6.5V, +3.3V → 3.9V ~ 4.3V, +12V → 13.3V ~ 15V
* SHORT CIRCUIT PROTECTION: +5V, +12V, +3.3V, -12V / AUTO-RECOVERED: +5VSB
* OVER CURRENT PROTECTION
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: TO MEET UL&CUL, TUV, CCC
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
* REMOTE ON/OFF CONTROL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module