Search:
N+1 RedundantS1Z2-5800K2V

800W

Server ,Workstation ,IPC ,Blade server ,Communication

240x85x82(mm)
9.45x3.35x3.23(inch)

VOLTAGE: 90 ~ 264 VAC
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 12A/6A MAX.(RMS) FOR 115/230 VAC
INRUSH CURRENT: 15A/30A MAX.FOR 115/230 VAC PER MODULE (at 25 degrees ambient cold start for each power unit)
POWER FACTOR CORRECTION: PFC CAN REACH THE
TARGET OF 95% AT 230V, FULL LOAD


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0 36 ±5% ±1% ±50mV
+3.3V 0 31 ±5% ±1% ±50mV
+12V 2 66 ±5% ±1% ±120mV
-12V 0 0.5 ±5% ±1% ±120mV
+5VSB 0.1 3 ±5% ±1% ±50mV
+5V and +3.3V Max. Power: 210W Total Power: 800W(MAX)

* TEMPERATURE RANGE: OPERATING 0℃~50℃, STORAGE -20℃~80℃
* EFFICIENCY: SHALL BE 88% @230V, FULL LOADING
* OVER POWER PROTECTION: 105~150%
* OVER VOLTAGE PROTECTION: +12V→+12.8V~+15.6V; +5V→+5.7V~+6.5V; +3.3V→+3.7V~+4.1V
* OVER CURRENT PROTECTION: +12V: 110~150%
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER: FCC CLASS A, CISPR22 CLASS A
* MEET SAFETY: UL, CUL, TUV, CCC

* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.