Search:

    keywords  
  • MP1S-6300V(300W)
    Dimension:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
    INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
    INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
    POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
    95% AT 115/230VAC, FULL LOAD
    MP1S-6400V(400W)
    Dimension:250x81.5x40.3(mm) / 9.84 x3.21x1.59(inch)
    INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
    INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
    POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
    95% AT 115/230VAC, FULL LOAD
    MPSM-5500V(550W)
    Dimension:160x150x86(mm) / 6.3 x5.9x3.39(inch)
    VOLTAGE: 90 ~ 264 VAC FULL RANGE
    FREQUENCY : 47 ~ 63 HZ
    INPUT CURRENT: 8A FOR 115VAC; 4A FOR 230VAC
    INRUSH CURRENT: 20A MAX. FOR 115 VAC; 40A MAX. FOR 230 VAC
    PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
    THE POWER SUPPLY SHALL INCORPORATE UNIVERSAL POWER
    INPUT WITH ACTIVE POWER FACTOR CORRECTION, WHICH
    SHALL REDUCE LINE HARMONICS IN ACCORDANCE WITH
    THE EN61000-3-2 STANDARDS.
    MP1S-5300V(300W)
    Dimension:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
    INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
    INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
    POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
    95% AT 115/230VAC, FULL LOAD
    MP1S-5220V(220W)
    Dimension:190x81.5x40.3(mm) / 7.48 x3.21x1.59(inch)
    VOLTAGE:90~264VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:3.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC
    INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC
    POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF
    95% AT 115/230VAC, FULL LOAD
    MQ1D-5120V(120W)
    Dimension:190x83.8x40(mm) / 7.48 x3.3x1.57(inch)
    VOLTAGE: 90~264VAC FULL RANGE
    FREQUENCY: 47~63HZ
    INPUT CURRENT:2A (RMS) FOR 115 VAC
    1A (RMS) FOR 230 VAC
    INRUSH CURRENT:35A MAX. FOR 115 VAC
    70A MAX. FOR 230 VAC
    MPSM-5600V(600W)
    Dimension:160x150x86(mm) / 6.3 x5.9x3.39(inch)
    VOLTAGE: 90 ~ 264 VAC FULL RANGE
    FREQUENCY : 47 ~ 63 HZ
    INPUT CURRENT: 10A FOR 115VAC; 5A FOR 230VAC
    INRUSH CURRENT: 20A MAX. FOR 115 VAC; 40A MAX. FOR 230 VAC
    PFC CAN REACH THE TARGET OF 95% @230V, FULL LOAD
    THE POWER SUPPLY SHALL INCORPORATE UNIVERSAL POWER
    INPUT WITH ACTIVE POWER FACTOR CORRECTION, WHICH
    SHALL REDUCE LINE HARMONICS IN ACCORDANCE WITH
    THE EN61000-3-2 STANDARDS.
    MHU2-5400V(400W)
    Dimension:150x140x86(mm) / 5.91 x5.51x3.39(inch)
    VOLTAGE:100~240VAC FULL RANGE(WITH ±10% TOLERANCE)
    FREQUENCY:47~63HZ
    INPUT CURRENT:6A (RMS) FOR 115 VAC
    3A (RMS) FOR 230 VAC
    INRUSH CURRENT:20A MAX. FOR 115 VAC
    40A MAX. FOR 230 VAC
     1 2  

zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module