Search:
Redundant modulePSS-2C00V

1200W

Server ,Workstation ,Storage System

310x61x40.5(mm)
12.2x2.4x1.59(inch)

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:15A (RMS) FOR 115 VAC
7.5A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC
30A MAX. FOR 230 VAC


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 2.0 100 ±5% ±1% 120mV
+5VSB 0.1 4 ±5% ±1% 50mV


* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:10mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1800 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1800 VAC FOR 1 SECOND
* EFFICIENCY:83% TYPICAL,AT 115VAC FULL LOAD
86% TYPICAL,AT 230VAC FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +12V→13.2V~15V
* SHORT CIRCUIT PROTECTION: +12V
* SAFETY : TO MEET UL, CUL, TUV
* REMOTE ON/OFF CONTROL
THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STAND BY).
AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
* COOLING : TWO 38mm DC FANS


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module