Search:
Redundant moduleGIN-3420V

420W

Server ,Workstation ,Storage System

250x79x40.5(mm)
9.84x3.11x1.59(inch)

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:7A/3A (115 / 230 VAC) POWER MODULE
INRUSH CURRENT:35/70A MAX. FOR 115/230 VAC POWER MODULE


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+12V 2 48 ±5% ±1% 120mV
-12V 0 0.8 ±10% ±1% 120mV
+5VSB 0.1 3.5 ±5% ±1% 50mV


* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃
* HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 60 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 60 SECOND
* EFFICIENCY:TYPICAL >82% AT 115VAC, 20%~100% MAX LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS
* OVER POWER PROTECTION:110% ~ 180%
* OVER VOLTAGE PROTECTION:+12V→13.3V~14.3V
* LEAKAGE CURRENT: 3.5MA MAX AT NOMINAL VOLTAGE 250VAC
* SHORT CIRCUIT PROTECTION:SHUT DOWN AND LATCH OFF
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: TO MEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL
THE POWER SUPPLY SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE/ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY).
AS LOGIC LEVEL IS LOW,OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH,OUTPUTS VOLTAGE WERE DISABLE.
* N+1 REDUNDANCY FUNCTION
* HOT-SWAPPABLE FUNCTION
* CURRENT/BALANCE LOAD SHARING DESIGN
* ISOLATION: BUILT-IN IN POWER MODULE
* POWER FACTOR CORRENTION: ACTIVE (MEET IEC-1000-3-2)
* COOLING: 40mm DC FANS (one module)


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module