Search:
Mini RedundantMRH2-5930V0H

930W

Server ,Workstation ,Storage System

280x150x86(mm)
11.02x5.91x3.39(inch)

VOLTAGE: 90 ~ 264 VAC FULL RANGE.
FREQUENCY: 47 ~ 63 Hz.
STEADY-STATE CURRENT: 15A/10A AT ANY LOW/HIGH
RANGE INPUT VOLTAGE
INRUSH CURRENT: 15A MAX. FOR 115 VAC , 30A MAX.
FOR 230 VAC (AT 25 DEGREE C AMBIENT COLD START FOR EACH POWER UNIT)
PFC: UP TO THE TARGET OF 95% @110V, FULL LOAD


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 1.0 36 ±5% ±1% 50mV
+12V 2 77.5 ±5% ±1% 120mV
-12V 0 0.5 ±5% ±1% 120mV
+3.3V 1.0 31 ±5% ±1% 50mV
+5VSB 0.1 3 ±5% ±1% 50mV
TOTAL MAX OUTPUT OF +5V AND +3.3V NOT EXCEED 210W
POWER MODULE TOTAL OUTPUT POWER NOT EXCEED 930W


* TEMPERATURE RANGE: OPERATING 0℃~50℃; STORAGE TEMPERATURE: -20℃~80℃
* EFFICIENCY: TYPICAL 82% AT 115V FULL LOAD, TYPICAL 84% AT 230V FULL LOAD
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240VAC AND 60Hz.
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION: 110%~160%
* OVER VOLTAGE PROTECTION
* OVER CURRENT PROTECTION
* SHORT CIRCUIT PROTECTION
* SAFETY: TO MEET UL, TUV, CB, CCC, RFI/EMI STANDARDS
* REMOTE ON/OFF CONTROL


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module