Search:
Micro RedundantDM1Y2-5150V2H

150W

Server ,Workstation ,Storage System ,IPC ,Communication ,Networking

275x106x41.3(mm)
10.83x4.17x1.63(inch)

VOLTAGE:-36 ~ -72VDC
FREQUENCY:DC
STEADY-STATE CURRENT: :-36 ~ -72VDC / 6~3 AMP (4 AMP AT 48VDC)
INRUSH CURRENT: 40A MAX. @-48VDC INPUT
(AT 25DEGREES AMBIENT COLD START FOR EACH POWER UNIT)


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 10 ±5% ±1% 50mV
+12V 2 12 ±5% ±1% 120mV
-12V 0 0.3 ±10% ±1% 120mV
+3.3V 0.5 10 ±5% ±1% 50mV
+5VSB 0 2 ±5% ±1% 50mV


* TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃
* HOLD UP TIME:1.6mS MIN. AT FULL LOAD & NOMINAL INPUT VOLTAGE
* EFFICIENCY: TYPICAL 80% AT -48VDC FULL LOADING
* OVER POWER PROTECTION: 110~160%
* OVER VOLTAGE PROTECTION
* SHORT CIRCUIT PROTECTION
* REMOTE ON/OFF CONTROL
* REMOTE SENSING DESIGN
* FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
* EMI NOISE FILTER: FCC CLASS A , CISPR 22 CLASS A
* SAFETY:TO MEET UL, CUL, TUV, CCC


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module