N+1 RedundantG1W2-5760V2V

760W

Server ,Workstation ,Storage System ,IPC

300x101.2x84(mm)
11.81x3.98x3.31(inch)

VOLTAGE: 90~264VAC, FULL RANGE
FREQUENCY: 47Hz~63Hz
INPUT CURRENT: 11A/5.5A MAX AT ANY LOW/HIGH INPUT VOLTAGE
INRUSH CURRENT: 40A/60A @ 115/230VAC (25℃)
POWER FACTOR CORRECTION: 95%@115/230VAC, FULL LOAD


Output VoltageTD Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P]
+5V 0.5 32 ± 5% ± 1% 50mV
+12V 2 62 ± 5% ± 1% 120mV
-12V 0 0.8 ± 5% ± 1% 120mV
+3.3V 0.5 32 ± 5% ± 1% 50mV
+5VSB 0.1 3.5 ± 5% ± 1% 50mV
+5V AND +3.3V TOTAL OUTPUT NOT EXCEED 190W
TOTAL OUTPUT MAX: 760W


* TEMPERATURE RANGE: OPERATING: 0~40℃, STORAGE: -20℃~80℃
* EFFICIENCY: 85% TYPICAL AT 230VAC FULL LOAD
* REMOTE ON/OFF CONTROL
* OVER POWER PROTECTION:110%~160%
* OVER VOLTAGE PROTECTION: +5V→5.7~6.2V, +3.3V→3.7~4.1V, +12V→13.3~14.3V;
* SHORT CIRCUIT: +5V, +3.3V, +12V, -12V, +5VSB
* OVER CURRENT PROTECTION:110~150%
* SAFETY: TO MEET UL, CUL, TUV, CCC
* LEAKAGE CURRENT: 3.5mA. MAX. AT NOMINAL VOLTAGE 240VAC AND 60Hz


*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.

 


zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module