【Medical】MP1S-5300V
300W
Server ,Workstation ,Storage System ,IPC
190x81.5x40.3(mm)
7.48x3.21x1.59(inch)
INPUT CHARACTERISTICS:VOLTAGE:90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:4.5A (RMS) FOR 115 VAC / 2.0A (RMS) FOR 230 VAC INRUSH CURRENT:70A MAX. FOR 115 VAC / 140A MAX. FOR 230 VAC POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% AT 115/230VAC, FULL LOAD
‧TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE –20℃~80℃ ‧HOLD UP TIME:16mS MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE ‧EFFICIENCY:80~84% TYPICAL AT 115V, FULL LOAD ‧POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1mS ‧OVER POWER PROTECTION:110~160% MAX ‧OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V ‧OVER CURRENT PROTECTION; +3.3V→18.7~27.2A, +5V→19.8~28.8A, +12V→>26.4~38.4 ‧SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB ‧SAFETY : TO MEET UL60601, TUV EN-60601, RFI/EMI STANDARDS ‧EMI NOISE FILTER: FCC CLASS B, CISPR22(EN55022) CLASS B ‧COOLING: 40mm DC FAN *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module