【Micro Redundant】M1S2-5551V4H
550W
Server ,Workstation ,Storage System
355x106x41.3(mm)
13.98x4.17x1.63(inch)
VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:5A(RMS)FOR HIGH RANGE INPUT VOLTAGE 10A(RMS)FOR LOW RANGE INPUT VOLTAGE INRUSH CURRENT:20A MAX. FOR 132 VAC PER MODULE 40A MAX. FOR 264 VAC PER MODULE
* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃ * HOLD UP TIME:12mS MIN. AT FULL LOAD & 115 VAC INPUT VOLTAGE * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 minute, INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY:84% MAX. TYPICAL AT FULL LOAD * POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION:+5V→5.8V~6.9V,+3.3V→3.9V~4.6V ,+12V→13.9V~16.4V * OVER CURRENT PROTECTION: +3.3V→27.5~37.5A, +5V→27.5~37.5A, +12V→49.5~67.5A * SHORT CIRCUIT: +12V, -12V, +3.3V, +5V, +5VSB * REMOTE ON/OFF CONTROL * EMI : FCC CLASS A , CISPR 22 CLASS A * SAFETY:UL , TUV IEC60950-1, CCC * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * MEET IEC-1000-3-2 CLASS D (ACTIVE PFC) * LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * COOLING: ONE 40mm DC FANS (MODULE) *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
keywords:zippy,1U Redundant,1U Single,2U Redundant,2U Single,3U Single,Cloud Power,Easy Swap,Medical,Micro Redundant,Mini 1U Single,Mini Redundant,N+1 Redundant,Open Frame,PS2,PS2*2 Redundant,PS2+,Redundant module