【1U Redundant】DR1S2-5380V4H
380W
Server ,Workstation ,Storage System ,IPC ,Communication ,Networking
230x176x41.8(mm)
9.06x6.93x1.65(inch)
VOLTAGE:-36 ~ -72VDC FREQUENCY: DC STEADY-STATE CURRENT: 15/7A MAXIMUN AT ANY LOW/HIGH RANGE INPUT VOLTAGE INRUSH CURRENT: 70A MAX. @-48VDC INPUT (AT 25DEGREES AMBIENT COLD START) START UP CURRENT: 13AMPS MAX. @ -48VDC INPUT
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STOREAGE -20℃~80℃ * HOLD UP TIME:1.6mS MIN. * DIELECTRIC WITHSTAND:INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAME GROUND 1500 VAC FOR 1 MINUTE * EFFICIENCY: POWER SUPPLY EFFICIENCY TYPICAL >80% AT -48VDC * OVER POWER PROTECTION: 110~160% * OVER VOLTAGE PROTECTION:+3.3V→3.6V~5V,+5V→5.6V~6.7V,+12V→13V~17V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V * REMOTE ON / OFF CONTROL * REMOTE SENSING DESIGN * BALANCE LOAD SHARING DESIGN * HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION * ISOLATION: BUILT-IN THE POWER MODULE * FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL * EMI NOISE FILTER: FCC CLASS A , CISPR 22 CLASS A * SAFETY:MEET UL, CUL, TUV, CCC *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.